Equipment Failure Procedure
PD-31 Equipment Drain & Waste Collection System 10/22/62
A. Waste Transfer Pump Becomes Inoperative
- 1. The reactor plant may continue to be operated in a normal manner if the waste water
inventory does not become excessive and if normal makeup remains available.
- 2. Tag out the pump controls.
- 3. Monitor the levels in the lab waste tank, waste storage tanks, innerbottom tanks,
containment drain tank, effluent condensing tank, and containment vessel very closely.
- 4. IF the water inventory becomes excessive or if the rate of leakage or collection
starts to increase, shut the reactor down and repair the pump.
- 5. If normal makeup fails, shut the reactor down to effect repairs. An emergency source
of makeup must be set up to effect cooldown.